PDG51
Pre departure generator check on Cat 51
Task Card Description
0
On a cold radiator, open the radiator cap and LOOK INSIDE. You should see coolant/liquid in the radiator. If low, refill with GREEN coolant only. When finished, put the radiator cap back on and MAKE SURE IT IS CLOSED TIGHT.
PDG51
1
Check the engine oil level using the DIPSTICK. If the oil is below MIN, add oil through the OIL FILL CAP ON TOP OF THE VALVE COVER. Do NOT pour oil into the dipstick tube. When finished, reinstall the oil fill cap tightly and put the dipstick back in completely.
PDG51
2
Push on the belt with your finger. It should feel tight, not loose. If you’re not sure, take a picture and report it. Do not adjust it
PDG51
3
Make sure shore power is disconnected
PDG51
4
Make sure all generator loads are OFF at the master switch. Do not start the generator under load.
PDG51
5
START GENERATOR — Press and hold the TOP of the large black generator switch until the generator starts. Usually about 15 seconds.
PDG51
6
Immediately confirm that seawater is coming out of the exhaust/cooling discharge. NO WATER = SHUT DOWN GENERATOR IMMEDIATELY.
PDG51
7
Once the generator is running normally and cooling water is flowing, switch the generator load ON.
PDG51
8
Turn on the air-conditioning units.
PDG51